1. Safety Instructions

  1. Read Before Use: Carefully read all instructions before installation or operation.

  2. Qualified Personnel Only: Installation, commissioning, and maintenance must be done by certified electricians.

  3. Electrical Shock Hazard: Disconnect AC and DC power before servicing. Avoid touching live terminals.

  4. Fire Risk: Keep the inverter away from flammable materials.

  5. Grounding: Connect the inverter to a proper ground according to local regulations.

  6. Protective Equipment: Use insulated gloves and safety goggles when handling the inverter.

2. Product Overview

  • Model: SMA SMC SB Tripower

  • Type: Three-phase photovoltaic inverter

  • Max AC Power: 11 kW

  • Input Voltage: DC 150–1000 V

  • Output Voltage: AC 400 V / 50 Hz

  • Efficiency: Up to 98%

Components:

  • LCD display and navigation buttons

  • DC input terminals (PV+) and (PV−)

  • AC output terminals (L1, L2, L3, N)

  • Communication ports (RS485, Ethernet)

  • Cooling fan and ventilation slots

3. Installation Instructions

  1. Mounting Location:

    • Indoor or sheltered outdoor area.

    • Ensure adequate airflow (minimum 10 cm from walls).

  2. Mounting:

    • Secure the inverter on a wall or mounting frame using SMA-supplied brackets.

  3. DC Wiring (PV Input):

    • Connect PV+ and PV− from the solar modules to the inverter.

    • Verify correct polarity.

  4. AC Wiring (Grid Connection):

    • Connect L1, L2, L3, and N to the AC distribution board.

    • Install a dedicated circuit breaker for the inverter.

  5. Grounding:

    • Connect the grounding terminal to the system ground according to CEI 0-21 standard.

4. Commissioning

  1. Switch on DC and AC power.

  2. The LCD will display the startup screen.

  3. Follow the on-screen setup wizard to:

    • Select language

    • Set grid parameters (CEI 0-21)

    • Enter PV system size

  4. Confirm PV voltage and grid connection.

  5. Verify there are no error messages. The inverter will enter Operation Mode.

5. Operation

  • LCD Display: Shows real-time voltage, current, power, energy yield, and status messages.

  • Buttons:

    • Enter/OK – confirm selections

    • Arrow Keys – navigate menus

  • Normal Operation: Converts DC from PV modules to AC for the grid automatically.

6. Maintenance

  • Visual Inspection: Check monthly for dust, debris, or loose connections.

  • Cleaning: Wipe with a dry cloth; avoid water or chemical solvents.

  • Firmware Updates: Can be performed via SMA Sunny Portal or USB drive.

7. Troubleshooting

Symptom Possible Cause Solution
No AC output Grid failure Check grid voltage
Error code on LCD Overvoltage, overload, or PV fault Reduce PV input, reset inverter
Low power Shading, dirty panels Clean modules, adjust orientation

8. Technical Specifications

  • Max DC voltage: 1000 V

  • MPPT voltage range: 200–800 V

  • Nominal AC voltage: 400 V, 50 Hz

  • Max AC current: 16 A

  • Efficiency: up to 98%

9. Storage & Transport

  • Store in a dry, ventilated area.

  • Protect from shocks and vibrations.

  • Temperature range: −25°C to +60°C.

 